Screw thread tolerance is the permitted range for thread dimensions — chiefly pitch diameter, major diameter and minor diameter — that determines whether a screw and its mating thread assemble without binding, stripping or loosening. For ISO metric fasteners, the general-purpose fit is 6H internal / 6g external, and a drawing that says only "M6" without a tolerance class is not a complete specification. This guide explains how buyers should read those classes, how plating changes them, and how to check a batch before it reaches the assembly line.
Quick answer: what should a buyer remember?
Screw thread tolerance is not a single number. It combines a tolerance grade (how wide the permitted band is) with a tolerance position (where that band sits relative to the nominal thread). The same M6 screw can be made to 6g, 6h or 4g6g and behave differently in the same nut. Ask your supplier which standard, which class and which diameters are controlled, then ask how the parts are gauged after coating. Those three answers separate a real specification from a catalogue description.
ISO 965-1:2013 defines the tolerance system for ISO general purpose metric screw threads conforming to ISO 261, and ISO 1502 covers the gauges and gauging practice used to verify them. You do not need to memorise the limit tables, but you do need to know that the class on the drawing, the plating on the part and the gauge on the inspection bench must all refer to the same requirement.
What screw thread tolerance actually controls
A metric thread is defined by a 60° basic profile, and the tolerance system assigns limits to three diameters:
- Major diameter — the outside diameter of an external thread, or the root diameter of an internal thread.
- Pitch diameter — the diameter at which the thread flanks are half the thread height apart. This is the dimension that most directly controls fit, because it governs how the flanks contact under load.
- Minor diameter — the root diameter of an external thread, or the bore of an internal thread. On small screws it also affects stripping strength and how the thread starts in a tapped hole.
Two threads can share the same nominal size and still fail to mate. If the external pitch diameter sits at the top of its band and the internal pitch diameter at the bottom of its band, the parts interfere; if both sit at the opposite extremes, the joint feels loose and loses preload. Screw thread tolerance classes exist to keep that combination inside a known, inspectable range rather than leaving it to the two factories to interpret separately.
How to read a thread class: 6g vs 6h vs 6H
A class designation has two parts. The number is the tolerance grade: a smaller number means a narrower band and a tighter, more expensive part. The letter is the tolerance position: lowercase letters apply to external threads (screws, bolts, studs) and uppercase letters to internal threads (nuts, inserts, tapped holes). The letter also sets whether an allowance is applied, which is the gap between the nominal size and the maximum material limit.
This is why "6g" and "6h" are not interchangeable. A 6g external thread carries a small negative allowance at the maximum material limit, so the largest permitted screw is slightly below nominal. A 6h external thread has no allowance: its maximum is nominal. Both are grade 6, but 6g leaves room for coating and for normal assembly, while 6h is used where a tighter, essentially zero-allowance fit is intended and the parts are usually uncoated or selectively coated. Every screw thread tolerance decision should state which of these two positions the joint needs.
| Class | Applies to | Allowance / position | Typical use |
|---|---|---|---|
| 6H | Internal thread | No fundamental deviation; band above nominal | General-purpose nuts, inserts and tapped holes |
| 6g | External thread | Small negative allowance at maximum material | General-purpose screws and bolts, including thin coatings |
| 6h | External thread | No allowance; maximum equals nominal | Uncoated or precision assemblies needing minimum clearance |
| 6G | Internal thread | Positive allowance; band shifted outward | Coated or plated nuts, and threads tapped after finishing |
| 5g6g | External thread | Pitch diameter 5g, major diameter 6g | Plated or coated screws where a tighter pitch band is acceptable |
| 4g6g | External thread | Pitch diameter 4g, major diameter 6g | Instrumentation and precision mechanisms |
When a drawing shows a combined designation such as 5g6g, the first figure and letter apply to the pitch diameter and the second pair to the major diameter. Reading it as one tolerance is a common source of quoting errors, because the supplier may control the major diameter to 6g while the buyer assumed the whole thread was 5g.
A short glossary buyers can send to suppliers
Procurement and engineering often use the same words for different things. These short definitions can be pasted into an RFQ so both sides mean the same requirement.
- Metric thread tolerance class: the combination of a tolerance grade and a tolerance position that defines the permitted limits for a metric thread, for example 6H for an internal thread or 6g for an external thread.
- 6g vs 6h thread: two external classes of the same grade 6, differing in allowance — 6g sits slightly below nominal at maximum material, while 6h reaches nominal.
- Thread ring gauge: a ring-shaped gauge used to check an external thread; the GO ring must engage the full thread and the NO-GO ring must not pass beyond the agreed limit.
- Go no go gauge: a matched pair of gauges that checks both the maximum and minimum material limits of a thread, rather than one limit alone.
- Minor diameter tolerance: the permitted range for the root diameter of an external thread or the bore of an internal thread, which affects stripping strength and thread starting.
- Plating thread fit: the change in fit caused by coating build-up on the thread flanks, which is why the gauging point before or after plating must be agreed.
- Custom screw thread inspection: the sample plan, gauge class and record format agreed for a made-to-drawing screw, including which diameters are checked and when.
Why plating is the most common cause of thread fit failures
Coating is applied after the thread is formed, and it grows on every surface. As a rule of thumb, a coating of t micrometres adds about 2t to a diameter, because the deposit builds on both flanks. A 6g external thread has an allowance that can absorb a thin coating; a 6H internal thread has none, so a plated nut or a tapped hole that is plated after tapping can close up enough to reject a screw that passed before finishing.
Plating thread fit is therefore a specification issue, not a polishing issue. The classic batch dispute runs like this: the supplier gauges the parts before plating and reports a pass, the buyer gauges after plating and reports a fail. Both readings can be honest. The specification, not the inspection result, is usually the defect. Practical options include:
- specify an internal class with clearance, such as 6G, when the nut or insert will be coated after tapping;
- specify 5g6g for external threads that will receive a measurable coating, and state the coating thickness range;
- tap or re-roll the internal thread after coating when the design allows it;
- mask threads that must remain uncoated, and say so on the drawing;
- state clearly whether gauging happens before or after coating, and with which gauge set.
Stainless steel adds a separate risk. Galling — the cold welding of mating stainless threads under pressure — can seize a joint even when both parts are inside tolerance. Tolerance alone does not solve it; thread lubrication, surface finish, installation speed and the hardness pairing of the two parts all matter. If your assembly uses stainless screws in stainless inserts, include a seating and removal test in the approval, not just a gauge check.
Go/no-go gauging: what a pass proves and what it does not
ISO 1502 describes the gauge design and gauging practice for ISO metric threads. In everyday inspection, two gauges are used for each thread:
- GO gauge — a thread ring gauge for external threads or a plug gauge for internal threads. It represents the maximum material limit and should engage the full thread length by hand.
- NO-GO gauge — represents the minimum material limit. It should not enter beyond a limited number of turns; a common shop-floor rule is no more than two turns, but confirm the exact acceptance rule in your inspection standard or customer requirement.
A GO pass proves that the thread is not too large; a NO-GO pass proves that it is not too small. Only both together say anything useful. A supplier who reports "go gauge OK" has checked one limit, not the thread. A go no go gauge pair also does not prove flank angle, surface finish, coating thickness, straightness, or that the screw will hold torque in your joint.
Gauges wear. A worn GO thread ring gauge accepts oversize parts, and a damaged NO-GO gauge rejects good ones. Ask for the calibration status and the gauge identification used on your lot, and make sure the gauge is the correct class for the part: a 6g ring gauge is not a valid check for a 6h screw, and a go/no-go pair made to a different standard is not a substitute.
| Check | Method | What a pass means | What it does not prove |
|---|---|---|---|
| External thread size | 6g or 6h GO ring gauge, then NO-GO ring gauge | Both limits are inside the specified band | Coating thickness, finish, straightness |
| Internal thread size | GO plug gauge, then NO-GO plug gauge | Bore is within the internal class | Thread depth, material strength, coating adhesion |
| Functional fit | Assembly with the actual mating part at specified torque | The joint assembles and seats in the real stack | Fatigue life or vibration resistance |
| Coating | Thickness measurement on a witness piece or part | Coating is inside the agreed range | Thread fit after coating unless gauged after coating |
| Lot consistency | Sampling per an agreed plan, with records | The lot meets the agreed acceptance criteria | Every piece; attribute sampling is not 100% inspection |
Batch fit checks a buyer can run without a metrology lab
Most importers do not need a full dimensional layout on every shipment. They need a small set of checks that catch the failures that stop production. A practical incoming routine looks like this:
- Keep an approved reference sample from the approved lot, sealed and labelled with drawing revision, material, finish and date. Compare appearance and thread start against it, not against memory.
- Gauge both limits on a sample from the beginning, middle and end of the production run, using calibrated gauges of the correct class.
- Assemble with the real mating part — the actual nut, insert or tapped panel — at the torque your line uses. This catches tolerance stack problems that a gauge cannot see.
- Check after coating, not only before, if the part is plated or painted. Record coating thickness on the same lot.
- Run a seating and removal test on a small number of joints, especially for stainless or painted threads, and note any seizure, chipping or torque drop.
- Retain the records — gauge IDs, calibration dates, sample size, results and photos — so a dispute can be resolved with evidence rather than opinion.
Where a formal acceptance procedure is needed, ISO 3269:2019 provides a purchaser-side acceptance inspection procedure for fastener lots when no prior agreement exists. It is a useful default, but it does not replace an agreed custom screw thread inspection plan for safety-critical or highly automated assembly, where the characteristics that matter should be named in the RFQ.
Common mistakes in screw thread tolerance specifications
- Writing only the nominal size. "M8 zinc plated" leaves the class, the coating thickness and the gauging point undefined. Two suppliers can quote the same line and deliver different fits.
- Assuming a GO gauge is a quality certificate. It checks one limit on the sample you measured, not the lot, the plating or the function.
- Measuring with a caliper. A caliper reads the major diameter; it cannot measure pitch diameter, which is the dimension that controls fit.
- Mixing internal and external letters. 6g is an external class; 6H is internal. A drawing that pairs them incorrectly invites a technically invalid quotation.
- Ignoring the coating sequence. Parts gauged before plating and installed after plating are the most common source of "it fit in the sample" complaints.
- Tightening the class to fix a loose joint. If the joint loosens, the cause may be preload, bearing surface, vibration or the mating material — not screw thread tolerance. A tighter class can raise cost and scrap without solving the problem.
- Forgetting the mating part. A screw inside its own tolerance can still fail in a nut or insert that is at the opposite limit. Specify the pair, not just the screw.
What to put on the drawing and in the RFQ
A complete screw thread tolerance requirement is short, but it must be explicit. Include:
- thread standard and size, for example ISO metric M6 × 1.0;
- metric thread tolerance class for each thread, and which diameters it applies to;
- thread length and whether it is full or partial;
- material grade and any mechanical property requirement;
- coating type, thickness range and whether threads are masked;
- the gauging point — before coating, after coating, or both;
- inspection method, sample size and record format;
- the mating part or mating thread, with its own class;
- packaging and identification requirements, including lot traceability.
If a field is unknown, mark it "to be confirmed after technical review" rather than leaving it blank. A blank field is not an agreement, and a supplier who fills it silently is guessing on your behalf.
How thread tolerance affects price and lead time
Tighter classes are not free. A 4g6g thread generally needs more consistent tooling, more frequent gauge checks and a higher scrap allowance than a 6g thread, and that cost appears in the unit price or in the yield. Post-coating re-tapping adds a handling step, and masking adds labour. None of these costs is automatically justified: the right question is which screw thread tolerance the joint actually needs, and whether the assembly can tolerate the wider, cheaper band.
Lead time is affected in a similar way. A standard 6g screw from existing tooling moves quickly; a new thread class, a new coating thickness or a post-plate re-tap can add a process step and a new approval. Buyers who specify the class late in the project often pay for it in schedule rather than in price.
Where JHFIX fits
JHFIX supplies machine screws, self-tapping screws, furniture connectors, nuts and hardware kits for furniture, cabinet and industrial assembly. Its published machine-screw range covers thread sizes from M1 to M12 and lengths from 3 mm to 200 mm for review, subject to the confirmed head geometry, mating thread and manufacturing route. Custom parts can be reviewed from a drawing or a sample, and the published MOQ for a confirmed machine-screw specification is 10,000 pieces.
The company describes in-house cold heading, tapping, stamping, injection moulding, assembly and quality inspection, and lists zinc plating, Ruspert coating, painting, electrophoretic coating, blackening and decorative plating as finish options for review. Those capabilities matter for screw thread tolerance because the forming, tapping and coating steps all influence the final fit; the practical question for a buyer is which of them will be used on your part and where the thread is gauged.
If your requirement involves a coated internal thread, a stainless pair that must not gall, or a class tighter than the general-purpose 6H/6g, send the drawing, the mating part and the inspection expectation together. The screw product range shows the current categories, and specialty and custom screws is the relevant starting point for made-to-drawing work. Existing buying guides on the JHFIX blog cover supplier audits and RFQ preparation if you are still building the requirement pack.
Frequently asked questions
Is 6g tighter than 6h?
No. Both are grade 6, so the band width is the same. The difference is position: 6g has a small negative allowance at the maximum material limit, while 6h's maximum equals nominal. In practice 6g is the more common choice for coated general-purpose screws because the allowance leaves room for the coating.
What does 6H mean on a nut or insert?
6H is an internal thread class with no fundamental deviation and a grade 6 band above nominal. It is the standard general-purpose internal fit and pairs with 6g external threads. If the nut will be plated after tapping, 6G is often more suitable because it provides clearance for the coating.
Can I check screw thread tolerance with a caliper?
Not reliably. A caliper measures the major diameter and cannot access the pitch diameter, which is the dimension that controls fit. Use a GO/NO-GO ring or plug gauge of the correct class, or a thread measuring method agreed with your supplier.
Why did the screws fit before plating but not after?
Because coating adds material to the thread flanks, roughly twice the coating thickness on a diameter. Internal threads lose clearance; external threads gain size. The fix is usually a specification change — an internal 6G class, a 5g6g external class, post-coating re-tapping, or masking — not a tighter inspection argument after shipment.
Does a GO gauge pass mean the whole batch is good?
No. It means the sampled parts passed one limit. It does not cover the NO-GO limit, the rest of the lot, the coating, the mating part or the function. Ask for both gauge results, the sample plan and the records.
Does a tighter thread class prevent loosening?
Not by itself. Loosening is usually a preload, vibration, bearing-surface or joint-stiffness issue. A tighter class changes assembly feel and cost, but it is not a locking feature. Use the joint design, torque strategy or a locking element to address loosening.
What should I send with an RFQ for a custom threaded part?
Send the drawing or sample, the thread standard and class, material, coating and thickness, the mating part and its class, estimated quantity, inspection expectation, packaging and destination. Mark anything unresolved as open rather than leaving it blank, so the supplier quotes the same requirement you intend to approve.
Conclusion
Screw thread tolerance is a specification decision before it is an inspection result. Decide the class, name the standard, define the coating sequence and the gauging point, and check both gauge limits on a sample that includes the real mating part. That sequence prevents most of the fit disputes that appear as "bad batches" when the real cause is an incomplete drawing.
If you are preparing a threaded part for quotation, send the drawing, the mating thread and the inspection requirement to the JHFIX team, or review the global sales and export page for how inquiries and export coordination are handled.